Alloy 400 (UNS N04400) is a nickel-copper alloy used for seawater, marine, and many chemical duties. ASTM B165 covers it as cold-worked seamless pipe and tube in an annealed or stress-relieved condition, and ASTM B829 sets the general requirements for dimensions, testing, and marking. Petrol Steel Co., Ltd. supplies N04400 seamless pipe in NPS [ ]–[ ], wall thicknesses from Schedule 5S to 80S [confirm range], and special walls on request, with EN 10204 3.1 certification and optional third-party inspection.
Quick specification table
| Item | Detail |
| Product standard | ASTM B165 (nickel-copper alloy seamless pipe and tube), edition as stated in your PO |
| General requirements | ASTM B829 |
| Alloy / UNS | Alloy 400 / UNS N04400 (EN: NiCu30Fe, 2.4360) |
| Form | Seamless pipe (NPS and schedule) and seamless tube (OD and wall) |
| NPS / OD | NPS [ ]–[ ] / [ ] mm |
| Wall thickness | [ ] mm, schedule 5S–80S [confirm]; others on request |
| Length | Cut-to-length or random [ ] m |
| Condition | Annealed (dull matte finish) or stress-relieved (thin light-to-medium-dark surface) |
| Ends | Plain cut and deburred |
| Coating | None |
| Testing | Hydrostatic or nondestructive electric test; tension; PMI |
| Certification | EN 10204 3.1 MTC |
| MOQ / lead time | [ ] kg / [ ] weeks, confirmed per RFQ |
Where Alloy 400 Earns Its Place, and Where It Does Not
Alloy 400 is roughly two-thirds nickel and one-third copper. It stays tough from low temperatures to moderate heat, and it is widely specified for seawater, brackish water, salt-laden atmospheres, alkalis, and hydrofluoric acid. Typical lines include seawater cooling and firewater on offshore platforms and ships, desalination and heat-exchanger feeds, and chemical plant lines carrying fluorine or caustic media. It is not a general-purpose answer. It does not perform well in oxidizing acids or in aerated ammonia solutions. In aerated hydrofluoric acid vapor, a stressed pipe can crack, which is one reason the delivery condition matters. If you are unsure, send us the medium, temperature, and aeration level before you choose a grade, and we will tell you plainly if Alloy 400 is wrong for the line. Check service limits against your own corrosion data.
What B165 Covers, and How B829 Fits In
B165 covers UNS N04400 as cold-worked seamless pipe and tube. Hot-worked material is available, but properties and tolerances must then be agreed between manufacturer and purchaser. The B829 document contains the general requirements that apply to a whole family of nickel-alloy seamless pipe and tube standards, including B165, along with the product standards for Alloy 825, Alloy 625, and Alloy C-22. If a requirement in B165 conflicts with B829, the B165 requirement wins. B829 defines seamless pipe as a round hollow with a continuous periphery, made to the dimensions commonly known as pipe sizes. The tube is ordered by outside diameter and wall. Inch-pound values are the standard, and metric values are for information only. We quote against the edition named in your order, so name it.
Annealed or Stress-Relieved? The Table That Decides
Ordering information in B165 includes the condition, so the choice has to be made at inquiry. Annealed pipe is soft, with a dull matte finish. A stress-relieved pipe is heat-treated below the annealing temperature to relieve most of the internal stress and carries a thin, light-to-medium-dark surface. The strength difference is large, and the ductility difference goes the other way. Where residual stress is a concern for service, buyers often ask for stress-relieved pipe. Where the pipe will be bent or formed, annealed is the safer choice. For small-diameter, light-wall tubes, the standard lists additional temps, so tell us the tube size.
| Condition | OD | Min tensile | Min yield (0.2%) | Min elongation |
| Annealed | 127 mm (5 in) and under | 480 MPa (70 ksi) | 195 MPa (28 ksi) | 35% |
| Annealed | Over 127 mm | 480 MPa (70 ksi) | 170 MPa (25 ksi) | 35% |
| Stress-relieved | All sizes | 585 MPa (85 ksi) | 380 MPa (55 ksi) | 15% |
Elongation in 50 mm (2 in) or 4D. Values from B165-05, Table 1. Confirm against the edition in your order.
Sizes: NPS, Schedule, and Wall Thickness
Pipe is ordered by nominal pipe size and schedule number, and the dimensions in B829 reprint the ANSI B36.19 pipe table. Other schedules may be furnished by agreement. The 5S and 10S walls do not permit threading to ANSI B1.20.1, which matters if your piping class calls for threaded ends. Tell us the length you need, because lengths are cut to length or random as agreed. A few common sizes are shown below, and the full table runs from NPS ⅛ upward.
| NPS | OD (mm) | Sch 10S (mm) | Sch 40S (mm) | Sch 80S (mm) |
| ½ | 21.34 | 2.11 | 2.77 | 3.73 |
| 1 | 33.40 | 2.77 | 3.38 | 4.55 |
| 2 | 60.33 | 2.77 | 3.91 | 5.54 |
| 4 | 114.30 | 3.05 | 6.02 | 8.56 |
| 6 | 168.28 | 3.40 | 7.11 | 10.97 |
| 8 | 219.08 | 3.76 | 8.18 | 12.70 |
| 12 | 323.85 | 4.57 | 9.52 | 12.70 |
Nominal wall thickness from B829-24, Table 1. At NPS 12, the 40S and 80S walls do not conform to ANSI B36.10.
Tolerances You Can Write Into the PO
Cold-worked pipe and tube follow Table 2 of B829, and tolerances widen as the diameter grows. Hot-worked pipe has a separate, wider table. For example, a hot-worked pipe of 25 to 48 mm OD allows +0.40 mm and −0.79 mm. Cut lengths are held to plus 3.2 mm, minus zero, below 50.8 mm OD, and plus 4.8 mm, minus zero, at 50.8 mm and above. These apply to lengths up to 7.3 m (24 ft). Beyond that, an extra 3.2 mm of over-tolerance is allowed for each additional 3 m, up to 12.7 mm. Ends are plain cut and deburred, and the material must be reasonably straight and free of bends and kinks.
| OD range (mm) | OD tolerance (mm) | Wall tolerance |
| Over 38 to 76 | ±0.25 | ±10% of nominal wall |
| Over 76 to 114 | ±0.38 | ±10% |
| Over 114 to 152 | ±0.51 | ±12.5% |
| Over 152 to 168 | ±0.64 | ±12.5% |
| Over 168 to 219 | ±0.79 | ±12.5% |
| Over 219 to 356 | +1.57 / −0.79 | +15% / −12.5% |
| Over 356 to 610 | +3.18 / −0.79 | +15% / −12.5% |
Cold-worked pipe and tube, B829-24, Table 2. A separate minimum-wall tolerance also applies.
Hydrostatic Test or Electric Test? Choose in the PO.
Each pipe is either hydrostatically tested or examined by a nondestructive electric test, and B165 lists the choice under ordering information, so state it. The hydrostatic test holds at least 1000 psi (6.9 MPa) for a minimum of 5 seconds, provided the fiber stress does not exceed the allowable value in the equation P = 2St/D. Any leak means rejection. The electric test uses eddy current to E426 or E571, or ultrasonic to E213. The reference defect is a drilled hole of up to 0.79 mm or a notch no deeper than 12.5% of the wall or 0.10 mm, whichever is greater. Ultrasonic testing is aimed at longitudinal defects and may not find circumferential ones. Two editions differ on who chooses: the 2005 edition of B165 leaves it to the manufacturer, while B829-24 says the purchaser must specify it. Settle that point in your order.
Lots of Retests and Documents
A lot for chemical analysis is one heat. For all other testing, a lot is all material of the same heat, nominal size, and condition, with a limit of 9,100 kg (20,000 lb). Where the heat cannot be identified, the limit is 227 kg (500 lb). If a lot fails mechanical tests, retests are made on double the original number of tubes. A failed lot can be reheat-treated and resubmitted, but not more than twice. Tension testing follows E8/E8M, and hardness and grain size can be tested on request. Pipes of 19 mm OD and larger and lengths over 914 mm are marked on each piece with the manufacturer, the UNS number, the ASTM specification, the heat number, and the nominal size. We supply an EN 10204 3.1 certificate, PMI, and third-party inspection by SGS, BV, or TÜV on request.
Alloy 400, 825, 625, or C-22: Choosing the Right Pipe
These four grades share one general-requirements document, so tolerances and test methods line up when you mix them in one order. Their strengths differ. Alloy 400 is chosen for seawater and hydrofluoric acid. The Alloy 825 seamless pipe, ASTM B423, suits oxidizing and mixed acid duties. The Alloy 625 seamless pipe offers higher strength and strong chloride pitting resistance. The Alloy C-22 seamless pipe, ASTM B622, is built for mixed oxidizing and reducing media. Send us the medium, temperature, and chloride level, and we will recommend one even if it is not the grade on this page.
Packing, Export, and How to Request a Quote
Pipes are marked, protected with end caps, and packed in export wooden cases, away from contact with carbon steel. We supply a packing list, certificate of origin, and any third-party release papers your destination requires. Petrol Steel Co., Ltd. supplies nickel alloy pipes, tubes, fittings, flanges, and bars to EPC contractors, fabricators, stockists, and trading partners. To start, send OD, WT, grade, and quantity, plus the medium, design temperature, test method (hydrostatic or electric), standard edition, and inspection requirements. We reply with a clear offer, a confirmed MOQ, and a realistic lead time. If Alloy 400 is not the right fit, we will say so.
Case example (optional): replace this line with one real project, such as “N04400 seawater cooling pipe delivered to [region], with SGS witnessing.” Delete it if you have no real case.
Related reading
- Alloy 825 seamless pipe, ASTM B423
- Alloy 625 seamless pipe
- Alloy C-22 seamless pipe, ASTM B622
- Nickel Alloy Range
Chemical composition (typical limits, wt.%)
| Ni | Cu | Fe | Mn | C | Si | S |
| 63.0 min | 28.0–34.0 | 2.5 max | 2.0 max | 0.3 max | 0.5 max | 0.024 max |
Not taken from your uploaded pages (B165 page 2 was missing). Verify against Table 2 of the edition named in your order.
RFQ block
Send OD, WT, grade & quantity. Also helpful: medium, design temperature, condition (annealed or stress-relieved), test method, B165/B829 edition, inspection requirement, and destination port.
[RFQ form] [Email] [WhatsApp / WeChat]
4. FAQ – Top 8
- What does ASTM B165 cover? Cold-worked seamless pipe and tube in UNS N04400. Hot-worked material is available by agreement.
- Annealed or stress-relieved? Annealed is soft with a matte finish. Stress-relieved is stronger and less ductile. Minimum tensile strength is 480 MPa for annealed and 585 MPa for stress-relieved.
- What does B829 add? The general requirements for dimensions, tolerances, testing, marking, and certification across nickel-alloy seamless pipe and tube.
- Hydrostatic test or electric test? Each pipe gets one of them. State your choice in order, because editions differ on who decides.
- What sizes, schedules, and tolerances do you supply? NPS [ ]–[ ], schedules 5S to 80S [confirm], tolerances per B829 Tables 2 and 4.
- What tests and certificates come with the pipe? EN 10204 3.1 MTC, hydrostatic or eddy current/UT, PMI, and SGS/BV/TÜV inspection on request.
- Alloy 400, 825, 625, or C-22: Which should I choose? It depends on the medium, temperature, and aeration. Send them, and we will recommend one.
- MOQ, lead time, and what do you need for a quote? Confirmed per RFQ [state your figures]. Send OD, WT, grade, quantity, medium, and test method.